Sterilization Principles – CSSD MCQ Questions and Study Notes
Sterilization principles explain how all viable microorganisms are destroyed. Practice free CSSD MCQ questions on this topic below.
Take the Sterilization Principles practice test All 45 chapters
Learning objectives
- Understand the key concepts of this chapter
- Apply them in safe practice
Study notes
Sterilization is a process that eliminates all forms of microbial life, including spores. Cleaning must come first because soil protects microorganisms.
Effectiveness depends on cleaning, exposure time, temperature or concentration, and contact with all surfaces. Spaulding classification guides the level of processing: critical items need sterilization, semi-critical need at least high-level disinfection, non-critical need low-level disinfection.
Important points
- Clean first
- Critical items require sterilization
- Bacterial spores are most resistant
- Sterility Assurance Level is 10^-6
Key terms
Spaulding classification Sterility Assurance Level Spore Bioburden
Practice MCQs on Sterilization Principles
Tap “Show answer” to check each answer and read the explanation. These practice questions are written for learning with AI assistance and may contain mistakes. Please report any error so it can be fixed.
Questions 1 to 10
1. Sterilization destroys:
- Only viruses
- All microorganisms including spores
- Only fungi
- Only bacteria
Show answer
Including spores.
2. Critical items contact:
- Sterile tissue or blood
- Bedrails
- Floors
- Intact skin
Show answer
Highest risk.
3. Critical items require:
- Sterilization
- Rinsing
- Nothing
- Wiping
Show answer
Sterile use.
4. Semi-critical items need at least:
- High-level disinfection
- No processing
- Dusting
- Wipe
Show answer
Mucous membranes.
5. The most resistant organisms are:
- Vegetative bacteria
- Enveloped viruses
- Bacterial spores
- Yeasts
Show answer
Spores resist most.
6. Cleaning precedes sterilization because:
- It shortens cycles
- It saves cost
- It is optional
- Soil protects microbes
Show answer
Residue blocks sterilant.
7. Sterility Assurance Level is typically:
- 10^-6
- 1
- 10^-1
- 10^-2
Show answer
One in a million.
8. Non-critical items touch:
- Sterile tissue
- Blood
- Bone
- Intact skin
Show answer
Low risk.
9. Sterilant must contact:
- Only handles
- Nothing
- All surfaces
- Only outer surfaces
Show answer
Penetration is essential.
10. Which affects sterilization success?
- Room paint
- Time, temperature, contact
- Packaging color
- Music
Show answer
Key parameters.
Questions 11 to 20
11. Which is generally regarded as the most resistant to disinfection and sterilization?
- Prions
- Vegetative bacteria
- Fungi
- Lipid viruses
Show answer
US practice: prions are more resistant than spores.
12. Flexible endoscopes are classified as:
- Critical
- Semi-critical
- Non-critical
- Sterile only
Show answer
US practice: Spaulding classification.
13. A Sterility Assurance Level of 10^-6 means:
- Six microorganisms remain per item
- All microorganisms are killed in six minutes
- One in ten probability of a viable microorganism
- One in a million probability of a viable microorganism
Show answer
US practice: standard for sterile devices.
14. Arthroscopes and laparoscopes are classified as:
- Non-critical
- Semi-critical
- Environmental
- Critical
Show answer
US practice: enter sterile tissue.
15. Under Spaulding classification, bed rails are:
- Semi-critical
- Critical
- Non-critical
- Sterile
Show answer
US practice: contact intact skin only.
16. Hot air oven sterilization is commonly done at:
- 80 °C for 5 minutes
- 121 °C for 60 minutes
- 100 °C for 10 minutes
- 160 °C for 60 minutes
Show answer
India practice: used for glassware, powders, oils.
17. Boiling water at 100 °C:
- Does not kill bacterial spores
- Is a sterilizer
- Sterilizes fully
- Kills prions
Show answer
India practice: it is disinfection only.
18. Which method is suitable for oils and powders?
- Boiling
- Chemical wipe
- Autoclave
- Hot air oven
Show answer
India practice: dry heat penetrates without moisture.
19. Gamma radiation is commonly used to sterilize:
- Instruments in OT
- Linen
- Disposable syringes and gloves
- Metal trays
Show answer
India practice: cold sterilization in industry.
20. 2% glutaraldehyde for high-level disinfection is typically used for:
- 5 seconds
- 1 minute
- Not used
- About 20 minutes
Show answer
India practice: follow manufacturer IFU; longer time for sterilization.
Questions 21 to 30
21. Disinfection does not necessarily kill:
- Bacterial spores
- Vegetative bacteria
- Some viruses
- Yeast
Show answer
Only sterilization does.
22. An antiseptic is used on:
- Floors
- Instruments
- Linen
- Living tissue
Show answer
Skin antisepsis.
23. A disinfectant is used on:
- Eyes
- Inanimate objects and surfaces
- Wounds
- Skin
Show answer
Not for tissue.
24. Low-level disinfection kills:
- Only viruses, never bacteria
- All bacterial spores and prions
- Nothing, it only cleans
- Most vegetative bacteria and some viruses
Show answer
Used for non-critical items.
25. Intermediate-level disinfection kills:
- Only spores
- Mycobacteria and most viruses and fungi
- Nothing
- Only dust
Show answer
Above low-level.
26. The D-value is the time to reduce a microbial population by:
- 90 percent (one log)
- 50 percent
- 1 percent
- 10 percent
Show answer
Used to compare resistance.
27. Each log reduction is a:
- One percent decrease
- Two-fold decrease
- Five percent decrease
- Ten-fold decrease
Show answer
10 to 1 reduction.
28. Moist heat compared with dry heat:
- Is slower
- Needs higher temperature
- Is weaker
- Kills at lower temperature and shorter time
Show answer
Steam transfers heat quickly.
29. Dry heat kills microbes mainly by:
- Oxidation
- Filtering
- Dissolving
- Freezing
Show answer
Needs high heat and time.
30. Sterilizing filtration is used for:
- Metal instruments
- Linen
- Heat-sensitive liquids and air
- Wraps
Show answer
Removes microbes physically.
Questions 31 to 40
31. Electron-beam sterilization is used industrially for:
- Linen
- Single-use medical products
- Hospital floors
- Water tanks
Show answer
A radiation method.
32. Pasteurization is:
- Packaging
- Sterilization
- Cleaning
- Not sterilization
Show answer
Reduces some microbes only.
33. Sterile means:
- Dry
- Disinfected
- Free of all viable microorganisms
- Clean-looking
Show answer
The strict definition.
34. The aim of aseptic technique is to:
- Add microbes
- Speed work
- Maintain sterility
- Clean floors
Show answer
Protects patients.
35. Process validation commonly includes:
- Counting trays and labels each shift
- Colour, weight and pack size checks
- Installation, operational and performance qualification
- Staff satisfaction surveys and menu reviews
Show answer
Proves the process works.
36. Inadequate cleaning raises the:
- Bioburden challenge
- Weight
- Shine
- Speed
Show answer
More microbes to kill.
37. Lumened devices are harder to sterilize because:
- The sterilant must reach the inside
- They are cheap
- They are light
- They are short
Show answer
Penetration challenge.
38. Heat-sensitive items need:
- No processing
- Dry heat
- Low-temperature sterilization
- Longer boiling
Show answer
Check the IFU.
39. Packaging must allow:
- Noise
- Light
- Water pooling
- Sterilant penetration
Show answer
And maintain sterility after.
40. A compromised package means the item is:
- Not sterile
- Better sterile
- Still sterile
- Dry only
Show answer
Reprocess it.
Questions 41 to 50
41. Implants are:
- Semi-critical
- Critical items
- Environmental
- Non-critical
Show answer
Contact sterile tissue.
42. Respiratory equipment contacting mucous membranes is:
- Semi-critical
- Environmental
- Critical
- Non-critical
Show answer
Needs at least HLD.
43. A stethoscope touching intact skin is:
- Non-critical
- Critical
- Sterile
- Semi-critical
Show answer
Low-level disinfection.
44. Cleaning reduces bioburden by:
- Removing most organisms and soil
- Adding detergent only
- Heating only
- Drying
Show answer
First step.
45. Biofilm is difficult because it:
- Resists disinfectants
- Dissolves in water
- Is sterile
- Is clear
Show answer
Remove by cleaning.
46. Material compatibility must be considered because:
- It looks good
- All materials are identical
- It saves time
- Some methods damage some materials
Show answer
Check the IFU.
47. The cycle chosen should match:
- The room
- Staff mood
- The color
- The load type and device IFU
Show answer
Use validated cycles.
48. Sterilization records are:
- Kept for traceability
- Optional
- Hidden
- Discarded
Show answer
Needed for audits.
49. The sterilization level needed depends on:
- The risk of the device
- Device color
- Brand only
- Staff lunch
Show answer
Spaulding logic.
50. A heat-resistant spore is used as a test organism because:
- It is cheap
- If it dies, less resistant organisms die
- It is rare
- It is blue
Show answer
A worst-case challenge.
Questions 51 to 52
51. Sterilant contact time is:
- The time between two cycles
- The exposure needed for the process to work
- The time spent packing the load
- The time the load takes to dry
Show answer
Follow the validated time.
52. Sterility is maintained by:
- The sterile barrier and correct handling
- Heat in storage
- Dust
- Wishing
Show answer
Until the package is opened.
Related chapters
- Previous: Packaging & Sterile Barrier Systems
- Next: Steam Sterilization
- Chapter 3: Instrument Inspection & Function Testing
- Chapter 4: Packaging & Sterile Barrier Systems
- Chapter 6: Steam Sterilization
- Chapter 7: Low Temperature Sterilization
Continue learning
CSSD interview questions Mock tests MCQ practice CSSD NABH checklist
Frequently asked questions
How many Sterilization Principles MCQs are available?
This page has 52 free MCQs on Sterilization Principles with answers and explanations. More are added over time.
Is Sterilization Principles practice free?
Yes. You can practice without login or payment.
Are these official CSSD exam questions?
No. They are original practice questions written for learning.